Our Product List
SIDE MOUNTED LEVEL SWITCH
[SERIES:MFmls01]

Technical Specification
Parameter | Value |
---|---|
Maximum Switch | Within 18 mm of level change |
Differential of Liquid at S.G. | 1 |
Minimum S.G. | 0.5 |
Switch Housing | Aluminum alloy |
Electric Connection | ½” NPT (other optional) |
Maximum Repeatability | ±1.5 mm |
Float & Linkage | SS304 / SS316 |
Max. Pressure |
A) 15 kg/cm² for YPL ‘A’ & ‘G’ flanges B) 100 kg/cm² for standard ASA/DIN flanges |
Max. Temperature |
A) Up to 150°C without cooling fins B) Above 150°C with cooling fins |
Minimum ID of Nozzle | More than 50 mm to enable the float to pass |
Maximum ID of Nozzle | 160 mm |
DESCRIPTION:
Side-mounted level switches are suitable for fitting into tanks or similar vessels for indicating or controlling the level of a liquid. These switches can either be supplied in weatherproof housing, explosion-proof housing, or for intrinsically safe applications.
PRINCIPLE OF OPERATION:
A change of liquid level correspondingly travels the float to extreme levels UP and DOWN. This movement of the float, in turn, causes a magnet to move into the proximity of a microswitch, resulting in switch actuation.